Comparison Of The Clinical Longevity Of Lithium Disilicate Crowns In Fixed Dental Prostheses

Authors

  • Alwan Zufar Faculty of Dentistry, Universitas Muhammadiyah Surakarta, Indonesia
  • Owin Bambang Wijanarko Faculty of Dentistry, Universitas Muhammadiyah Surakarta, Indonesia

DOI:

https://doi.org/10.55227/ijhet.v5i3.1226

Keywords:

Fixed Dental Prosthesis; Lithium Disilicate; Longevity; Survival Rate; Success Rate

Abstract

Tooth loss can impair mastication, phonetics, aesthetics, and quality of life, necessitating restorations that restore function and maintain long-term clinical performance. Fixed dental prostheses (FDPs) made of lithium disilicate are increasingly used because of their favorable mechanical and aesthetic properties. However, evidence regarding the durability and longevity of lithium disilicate restorations varies according to material type, clinical conditions, and evaluation parameters. This literature review aimed to examine the clinical longevity of lithium disilicate crowns used in fixed dental prostheses based on survival rate, success rate, mechanical strength, wear resistance, marginal adaptation, bond strength, and restoration-related complications. A literature review was conducted using a systematic approach based on the PRISMA 2020 guidelines. Literature searches were performed in PubMed, ScienceDirect, DOAJ, MDPI, Garuda, and Google Scholar for articles published between 2020 and 2025. Five studies were included in the review. The findings demonstrated that lithium disilicate exhibited favorable flexural strength and wear resistance, with good mechanical stability following chewing simulation. Marginal adaptation remained within clinically acceptable limits, while bond strength and translucency supported restoration performance. Clinical studies also reported high survival and success rates over six years. In conclusion, lithium disilicate demonstrates favorable clinical longevity as a restorative material for fixed dental prostheses, offering a balance between mechanical durability, long-term clinical performance, and aesthetic outcomes.

Downloads

Download data is not yet available.

References

Abdulrahman, S., Von See Mahm, C., Talabani, R., & Abdulateef, D. (2021). Evaluation of the clinical success of four different types of lithium disilicate ceramic restorations: a retrospective study. BMC Oral Health, 21(1), 625.

Al-Hamzi, M. A., Al-Badani, I. T. H., Al Kbous, E. H. M., Daghrery, A., Alhumaidi, A. M., & Al Moaleem, M. M. (2025). Twelve-month clinical outcomes of zirconia cores veneered with lithium disilicate crowns: a retrospective study. The Journal of Contemporary Dental Practice, 26(6), 540–550.

Alenezi, A., & Aloqayli, S. (2023). Technical complications with tooth ‑ supported fixed dental prostheses ( FDPs ) of different span lengths : an up to 15 ‑ year retrospective study. BMC Oral Health, 1–11. https://doi.org/10.1186/s12903-023-03121-9

AlMashaan, A., & Aldakheel, A. (2022). Survival of complete coverage tooth-retained fixed lithium Disilicate prostheses: a systematic review. Medicina, 59(1), 95.

Alshiddi, I. F. (2023). Survival rate and clinico-radiographic parameters around narrow-diameter dental implants for fixed dental prostheses in the posterior regions: A systematic review. Dental and Medical Problems, 60(2), 345–353.

Alsulimani, O., Yousief, S. A., Al-dabbagh, R. A., Attar, E. A., Bukhary, D. M., Algamaiah, H., Musawa, K., Subahi, A., Abuzinadah, S. H., Alhaddad, A. J., Alqahtani, W. M. S., Emam, N. M., Alqhtani, M. A., Elmarakby, A. M., Alsulimani, O., Yousief, S. A., Al-dabbagh, R. A., & Attar, E. A. (2025). The Effect of Chewing Simulation on Flexural Strength of Different Lithium Disilicate Ceramics The Effect of Chewing Simulation on Flexural Strength of Different Lithium Disilicate Ceramics. 1357. https://doi.org/10.2147/CCIDE.S504292

Aswal, G. S., Rawat, R., Dwivedi, D., Prabhakar, N., & Kumar, V. (2023). Clinical outcomes of CAD/CAM (lithium disilicate and zirconia) based and conventional full crowns and fixed partial dentures: A systematic review and meta-analysis. Cureus, 15(4).

Aziz, A., & El-mowafy, O. (2023). Six-year clinical performance of lithium disilicate glass-ceramic CAD-CAM versus metal-ceramic crowns.

Balet, A., Bjarnadottir, G. R., & Romandini, P. (2026). A Systematic Review and Meta-analysis Evaluating the Survival, Failure, and Complication Rates of Metal-Ceramic, Veneered, and Monolithic All-Ceramic Tooth-Supported Single Crowns—Part.

Bhagat, T., Shrestha, A., kumari Agrawal, S., Gautam, U., Sharma, D., Ghimire, B., Yadav, R., Agrawal, S., & Paudel, U. (2025). Impact of Tooth Loss on Oral Health Related Quality of Life among Geriatric Patients Attending a Tertiary Care Center of Koshi Province. Journal of BP Koirala Institute of Health Sciences, 8(2), 11–15.

D’Addazio, G., Santilli, M., Rollo, M. L., Cardelli, P., Rexhepi, I., Murmura, G., Husain, N. A. H., Sinjari, B., Traini, T., Özcan, M., & Caputi, S. (2020). Fracture resistance of Zirconia-reinforced lithium silicate ceramic crowns cemented with conventional or adhesive systems: An in vitro study. Materials, 13(9). https://doi.org/10.3390/MA13092012

Elsherbini, M., Sakrana, A. A., Amin, R. A., Diaa, M., Özcan, M., & Al‐Zordk, W. (2023). A micro‐computed tomography analysis of internal and marginal fits of fixed partial dentures: Effect of preparation finish line designs on monolithic zirconia and heat‐pressed zirconia‐reinforced lithium disilicate. Journal of Prosthodontics, 32(5), e90–e99.

Ferrini, F., Paolone, G., Laura, G., Domenico, D., Pagani, N., & Gherlone, E. F. (2023). SEM Evaluation of the Marginal Accuracy of Zirconia , Lithium Disilicate , and Composite Single Crowns Created by Different Materials.

Fitria, I., Gunawan, G., Al Annuri, Q. F., & Rifani, A. (2022). Fixed Prosthodontic Treatment of Patient with Anterior Deep Bite- A case report. Andalas Dental Journal, 10(2), 92–97. https://doi.org/10.25077/adj.v10i2.226

Hawthan, M., Larsson, C., & Chrcanovic, B. R. (2024). Survival of fixed prosthetic restorations on vital and nonvital teeth: A systematic review. Journal of Prosthodontics, 33(2), 110–122.

Killedar, S. M., Marwaha, J., Sinha, R. R., Devi, N. N., Langpoklakpam, C., & Neeraja, B. (2025). Wear Resistance and Surface Roughness of Hybrid Ceramic Crowns Compared to Lithium Disilicate: An In Vitro Study. Journal of Pharmacy and Bioallied Sciences, 17(Suppl 4), S3108–S3110.

Liu, Y., Huang, Y., Chu, S., Fu, Q., Liu, H., He, F., & Wang, Y. (2025). Optimal design of the retainer and connector for a lithium disilicate resin-bonded fixed partial denture: A finite element analysis study. The Journal of Prosthetic Dentistry.

Mazza, D. D. S. L. C., Pesqueira, P. A. A., & Pellizzer, P. E. P. (2022). Survival and complications of monolithic ceramic for tooth-supported fixed dental prostheses: A systematic review and meta-analysis. The Journal of Prosthetic Dentistry, 128(4), 566–574.

Mds, A. B., & Jensen, S. S. (2023). Resin-bonded fixed dental prosthesis versus implant- supported single crowns in the anterior region. July, 1197–1206. https://doi.org/10.1111/cid.13266

Saravi, B., Vollmer, A., Hartmann, M., Lang, G., Kohal, R.-J., Boeker, M., & Patzelt, S. B. M. (2021). Clinical performance of CAD/CAM all-ceramic tooth-supported fixed dental prostheses: a systematic review and meta-analysis. Materials, 14(10), 2672.

Srivastava, N., & Kumar, A. (2025). In vitro evaluation of shear bond strength and translucency of zirconia-reinforced lithium silicate and lithium disilicate. 54(1), 1935–1940.

Suci, A. W. E., Ratnasari, D., Dwisaptarini, A. P., & Elline, E. (2023). Fracture Toughness of Monolithic Zirconia and Lithium Disilicate CAD/CAM Endocrown. Journal of Indonesian Dental Association, 6(2), 105. https://doi.org/10.32793/jida.v6i3.968

Sulastri, S. (2024). EVALUASI KETAHANAN FRAKTUR PADA GIGI PASCA PERAWATAN ENDODONTIK YANG DIRESTORASI DENGAN RESIN KOMPOSIT BULK-FILL (IN-VITRO). Universitas Hasanuddin.

Surlari, Z., Virvescu, D., Carina, B., Iordache, C., Budală, D., Luca, E., Scurtu, M., & Țănculescu, O. (2020). Clinical study on oral hygiene in patients with fixed dental prostheses. Romanian Journal of Medical and Dental Education, 9(1), 1–4.

Syed, A., Parvez, K., Zubair Badshah, D. F. T., Bilal, M., & Mushtaq, M. A. (2026). Clinical Performance of CAD/CAM-Fabricated Crowns Compared with Conventional Metal-Ceramic Crowns. CME Journal Geriatric Medicine, 18, 595–601.

Tekin, Y. H., & Hayran, Y. (2020). Fracture resistance and marginal fit of the zirconia crowns with varied occlusal thickness. Journal of Advanced Prosthodontics, 12(5), 283–290. https://doi.org/10.4047/jap.2020.12.5.283

Wierichs, R. J., Kramer, E. J., Reiss, B., Roccuzzo, A., Raabe, C., Yilmaz, B., & Abou-Ayash, S. (2024). Longevity and risk factors of CAD-CAM manufactured implant-supported all-ceramic crowns-A prospective, multi-center, practice-based cohort study. Dental Materials, 40(11), 1962–1969.

Downloads

Published

2026-10-01

How to Cite

Alwan Zufar, & Owin Bambang Wijanarko. (2026). Comparison Of The Clinical Longevity Of Lithium Disilicate Crowns In Fixed Dental Prostheses. International Journal of Health Engineering and Technology (IJHET), 5(4). https://doi.org/10.55227/ijhet.v5i3.1226

Issue

Section

Health