The Role Of Substations As A Link Between Electrical Transmission And Distribution Systems

Authors

  • Diyajeng Luluk Karlina Universitas Sultan Ageng Tirtayasa

DOI:

https://doi.org/10.55227/ijhet.v5i4.1308

Keywords:

Substation, Transmission System, Distribution System, Protection System

Abstract

Substations are an essential part of the electric power system, serving as a link between electrical transmission and distribution systems. This study aims to analyze the role of substations in maintaining the reliability of electrical energy transmission and supporting the stability of electric power distribution systems. The approach applied in this study is a literature review, conducted by examining various scientific references, including national journals, books, and scientific papers relevant to the research questions. The references were obtained from academic databases such as Google Scholar, DOAJ, and ProQuest. The collected data were analyzed using descriptive and thematic analysis approaches to identify the functions, components, and influence of substations on electric power distribution systems. The results indicate that substations have several primary functions, including voltage transformation, power flow regulation, protection systems, and voltage quality control. The reliability of distribution systems is influenced by the performance of substation components, such as power transformers, circuit breakers, busbars, and OCR (Overcurrent Relay) and GFR (Ground Fault Relay) protection systems. Furthermore, faults such as short circuits, transformer overloads, and inadequate maintenance can affect the continuity of electrical energy distribution. Therefore, regular maintenance, optimization of protection systems, and the development of monitoring technologies are highly recommended to improve the efficiency and reliability of modern electric power systems.

Downloads

Download data is not yet available.

References

Annisa, S. C., & Mardiansah, A. (2023). Analisis Permasalahan Disconnecting Switch Pada Unit Induk Transmisi Jawa Barat. 10(2).

Corzine, K. A., & Member, S. (2017). A New-Coupled-Inductor Circuit Breaker for DC Applications. 32(2), 1411–1418.

Dewi, N., & Yusdartono, H. M. (2023). STUDI DROP TEGANGAN PADA JARINGAN DISTRIBUSI 20 KV ANTARA GARDU INDUK SIGLI DENGAN GARDU HUBUNG EXPRESS TRIENGGADENG MENGGUNAKAN. 12, 31–35.

E-issn, E. L. P., Teknik, J., Pratito, A. A., & Irawan, D. (2022). ANALISIS SETTING RELAY LINE DIFFERENTIAL GARDU INDUK PLTU GRESIK.

Feizifar, B., & Diagnosis, A. M. (2017). Condition Monitoring of Circuit Breakers : Current Status and Future Trends. 0–4.

Gianto, R. (2021). MODEL STEADY STATE PEMBANGKIT LISTRIK TENAGA ANGIN YANG BERBASIS PMSG UNTUK ANALISIS ALIRAN DAYA. 4, 134–142.

Harjian, M. R., Muljono, A. B., & Putra, R. R. E. (2025). MENGGUNAKAN METODE SECTION TECHNIQUE AND FAILURE MODE EFFECT & ANALYSIS ( FMEA ). 13(2).

Idriana, E., Putri, R., Meliala, S., Fariadi, D., Elektro, J. T., Teknik, F., Malikussaleh, U., & Utara, A. (2021). ANALISA SETTING KOORDINASI PROTEKSI OVER CURRENT RELAY PADA JARINGAN DISTRIBUSI DI PT . PLN ( PERSERO ) ULP PANGKALAN BRANDAN. 10, 22–29.

Isfihana, R., Suyono, H., & Hasanah, N. (2022). CONSTRAINT STABILITAS SISTEM AKIBAT INJEKSI HYBRID DISTRIBUTED GENERATION. 1, 1–8.

Kerusakan, I., Bay, P. M. T., Metode, M., Analyzer, B., & Kontak, T. (2021). Identification Damage of PMT 500KV BAY 7A1 Using the Breaker Analyzer and Contact Resistance Methods at the Substation. 5(2), 156–164.

Rauf, R., & Najif, H. (n.d.). STUDI ANALISIS PERBAIKAN JATUH TEGANGAN RENDAH DENGAN PEMASANGAN TRAFO SISIPAN PADA PT . PLN ULP. 14(2), 1078–1086.

Swierczynski, B., Gonzalez, J. J., Teulet, P., Freton, P., & Gleizes, A. (2004). Advances in low-voltage circuit breaker modelling. 37, 595–609. https://doi.org/10.1088/0022-3727/37/4/011

Wang, D. (2025). HIGH-VOLTAGE CIRCUIT BREAKER FAULT VOICEPRINT RECOGNITION BASED ON PROTOTYPE SIMILAR DOMAIN ADAPTIVE SPECTRAL MORPHOLOGICAL NEURAL NETWORK. 26(3). https://doi.org/10.29354/diag/206079

Yang, F., Wu, Y., Rong, M., Sun, H., Murphy, A. B., Ren, Z., & Niu, C. (2013). Low-voltage circuit breaker arcs — simulation and measurements. 273001. https://doi.org/10.1088/0022-3727/46/27/273001

Yasmin, S. Y., Permata, E., Vokasional, P., Elektro, T., Sultan, U., Tirtayasa, A., Yogyakarta, U. N., & Proteksi, S. (2022). SISTEM PROTEKSI SWITCH GEAR 5P1 _ 1S1 _ U5 UNTUK MOTOR CEMENT MILL DI PT. 1(1), 106–115.

Downloads

Published

2026-11-27

How to Cite

Diyajeng Luluk Karlina. (2026). The Role Of Substations As A Link Between Electrical Transmission And Distribution Systems. International Journal of Health Engineering and Technology, 5(4). https://doi.org/10.55227/ijhet.v5i4.1308